SAUDI KAYAN PETROCHEMICAL COMPLEX
Back
- Client:
- FLUOR/SAUDI KAYAN
- Final User:
- SAUDI KAYAN
- Plant Location:
- Jubail (KSA)
- Application:
- Intake water
- Circulation water
- Potable water
- Reactor type:
- L-type reactor (intake and circulation)
- U-type reactor (potable)
- ClO2 design production:
- 2x12 kg/h Reactor Intake
- 2x75 kg/h Reactor Cooling water
- 1x3 kg/h Reactor potable water
- Dosing strategy:
- Shot mode for Cooling and Intake plants
- 24 H Continuous mode for Potable plant
- Intake water treatment plant:
- Nos.1 HCl storage tank 30 m3
- Nos.1 NaClO2 storage tank 30 m3
- Nos.4 HCl dosing pumps 60 lt/h
- Nos.4 NaClO2 dosing pumps 60 lt/h
- Nos.2 Dilution water pumps
- Nos.2 ClO2 generators
- Circulation water treatment plant:
- Nos.1 HCl storage tank 50 m3
- Nos.1 NaClO2 storage tank 50 m3
- Nos.4 HCl dosing pumps 375 lt/h
- Nos.4 NaClO2 dosing pumps 375 lt/h
- Nos.2 Dilution water pumps
- Nos.2 ClO2 generators
- Potable water treatment plant:
- Nos.1 HCl storage tank 10 m3
- Nos.1 NaClO2 storage tank 10 m3
- Nos.2 HCl dosing pumps 0,4 lt/h
- Nos.2 NaClO2 dosing pumps 0,4 lt/h
- Nos.2 Dilution water pumps
- Nos.1 ClO2 generator
- Used chemicals:
- 31% sodium chlorite
- 31-33% hydrochloric acid
- Type of contract:
- Equipment supply
- Turn-key (EPC)
- Commissioning
- Chemicals supply
- Post start-up technical service
- Global Service